Aussie owned and operated, with 23+ years of industry experience, Gold Coast InfoTech is delighted to support all of your business technology requirements.

Gallery

Contacts

success@goldcoastinfotech.com.au

1800 291 071

KBArticles

HDX Volume control sync Server and Client broken

Situation:
Citrix Support the volume control sync / mute of a Desktop session to also control the HDX media volume playing out on the client.

Problem:
After upgrading to Citrix Receiver 3.0 this functionality stopped.
HDX Flash Content would be streamed to the client side and would play, but if the XenApp session volume was muted – the HDX content would continue to play – the only way to mute was via any flash enabled controls (if they existed).

If the XenApp session is ‘muted’ the HDX content will still stream to the end users desktop ignoring the controls in the session.

Most users do not notice or care

Resolution: (no permament solution found yet)
We have a call raised with citrix to investigate

Our temporary solution is rolling back clients to the 12.1 version of the citrix ICA Client.
Receiver 3.0 and Receiver 3.1 both do not sync volume controls.

This was tested on a Xen App 5.0 FR3 R01 farm and a brand spanking new XenApp 6.5 Farm – All failed with the Receivers 3.0 and 3.1.

We are not of the opinion this is related to anythign else in our environment other than the ICA Client / Receiver upgrade.

We await further results from citrix.

UPDATE
This feature has been removed as part of receiver 3.0 + as this was crashing the XP workstations / ica clients.

The feature is only availably in later model Clients OS (windows 7 for example) running the receiver, other wise ICA client 12.1 is the last client to support XP local HDX volume sync

Author

Customer

Comments (2)

  1. Wayne Seeliger
    24 May 2013

    Hi Jimmy, I have just finished building a new WES7 image and am finding the exact same issue. I understand Citrix removed this feature for Windows XP(e). but it should work on WES7. Any ideas how?

    Thanks.

    P.S. Nice blog.

    • scanjam
      24 May 2013

      Texas ranger,
      Have you tested on a full w7 device and not embedded?
      Also note the citrix desktop lock can also kill this..

      Ensure you have the latest edition of the citrix receiver and that no gpo’s could be affecting it during your testing.